用于40--60HZ交流電力系統(tǒng)中,與并聯(lián)電容器組配套串聯(lián)使用,以限制高次諧波引起的電容器組過電流及電容器組合閘涌流,保護電容器組穩(wěn)定運行,并改善電網(wǎng)波形,減少畸變率,保證供電質量。
Product Description
CKSC type dry iron core reactors are used in 40-60Hz AC power systems, in series with parallel capacitor banks to limit the overcurrent and surge current caused by high-order harmonics in capacitor banks, protect the stable operation of capacitor banks, improve the waveform of the power grid, reduce distortion rates, and ensure power supply quality.
Product features
In the power system, dry-type iron core reactors are used to compensate for the capacitive current of the transmission line, suppress the power frequency voltage rise and operating overvoltage caused by capacitive reactive power of the transmission line during light loads. The simultaneous connection of parallel reactors can reduce the latent current in the event of system grounding faults, which is beneficial for eliminating self excitation of the generator; No electromagnetic pollution to the surrounding environment; Low vibration and noise during movement.
Technical Parameter
Reactor model | Rated capacity(Kvar) | Rated voltage(kv) | Reactance rate(%) | Rated current(A) | Size(mm) | Weight(kg) | ||
Long | Width | Height | ||||||
CKSC-30/6-5 | 30 | 6 | 5 | 52 | 930 | 590 | 1121 | 410 |
CKSC-36/6-6 | 36 | 6 | 6 | 52 | 930 | 590 | 1121 | 410 |
CKSC-45/6-5 | 45 | 6 | 5 | 79 | 960 | 590 | 1041 | 510 |
CKSC-54/6-6 | 54 | 6 | 6 | 79 | 960 | 590 | 1041 | 510 |
CKSC-60/6-5 | 60 | 6 | 5 | 105 | 970 | 590 | 1013 | 550 |
CKSC-72/6-6 | 72 | 6 | 6 | 105 | 910 | 740 | 1101 | 510 |
CKSC-75/6-5 | 75 | 6 | 5 | 131 | 910 | 740 | 1101 | 510 |
CKSC-90/6-6 | 90 | 6 | 6 | 131 | 940 | 740 | 1241 | 640 |
CKSC-120/6-5 | 120 | 6 | 5 | 210 | 1060 | 740 | 1261 | 830 |
CKSC-144/6-6 | 144 | 6 | 6 | 210 | 990 | 740 | 1261 | 790 |
CKSC-180/6-5 | 180 | 6 | 5 | 315 | 1120 | 740 | 1355 | 1080 |
CKSC-200/6-5 | 200 | 6 | 5 | 350 | 1260 | 850 | 1281 | 1200 |
CKSC-216/6-6 | 216 | 6 | 6 | 315 | 1200 | 740 | 1317 | 1055 |
CKSC-240/6-6 | 240 | 6 | 6 | 350 | 1200 | 740 | 1317 | 1075 |
CKSC-90/10-4.5 | 90 | 10 | 4.5 | 105 | 1050 | 740 | 1103 | 720 |
CKSC-108/10-4.5 | 108 | 10 | 4.5 | 126 | 1050 | 740 | 1163 | 800 |
CKSC-120/10-6 | 120 | 10 | 6 | 105 | 1030 | 740 | 1151 | 770 |
CKSC-135/10-4.5 | 135 | 10 | 4.5 | 157 | 1060 | 740 | 1163 | 790 |
CKSC-144/10-6 | 144 | 10 | 6 | 126 | 1060 | 740 | 1240 | 845 |
CKSC-162/10-4.5 | 162 | 10 | 4.5 | 189 | 1110 | 740 | 1181 | 930 |
CKSC-180/10-4.5 | 180 | 10 | 4.5 | 210 | 1210 | 740 | 1230 | 1280 |
CKSC-180/10-6 | 180 | 10 | 6 | 157 | 1090 | 740 | 1240 | 960 |
CKSC-189/10-4.5 | 189 | 10 | 4.5 | 220 | 1210 | 740 | 1285 | 1280 |
CKSC-216/10-4.5 | 216 | 10 | 4.5 | 252 | 1110 | 740 | 1286 | 1070 |
CKSC-216/10-6 | 216 | 10 | 6 | 189 | 1360 | 740 | 1265 | 1060 |
CKSC-225/10-4.5 | 225 | 10 | 4.5 | 262 | 1360 | 740 | 1381 | 1180 |
CKSC-240/10-6 | 240 | 10 | 6 | 210 | 1330 | 740 | 1126 | 1000 |
CKSC-240/10-12 | 240 | 10 | 12 | 96 | 1350 | 850 | 1266 | 1150 |
CKSC-243/10-6 | 243 | 10 | 6 | 283 | 1360 | 740 | 1148 | 1180 |
CKSC-252/10-6 | 252 | 10 | 6 | 220 | 1350 | 740 | 1186 | 1190 |
CKSC-270/10-4.5 | 270 | 10 | 4.5 | 315 | 1290 | 740 | 1353 | 1400 |